| PROJECT TITLE | PROJ. NO. | PROJECT CLASSIFICATION | |||||||
| SCS Plant & System Expansion | 2-11-S | Sewer | |||||||
| DESCRIPTION: | |||||||||
| At this point in time, the St. Clements Shores Plant and System Expansion will be designed to serve houses with existing the areas failed septic systems only, however, the County is also looking at but has not yet approved serving the infill of existing lots of record. The total expansion for existing homes would be 149 EDU's. The treatment plant capacity would have to increase by 40% and would require additional Rapid-infiltration Basins (RIB's) plus the conversion of the facultative lagoons from storage to treatment lagoons to handle the increased flow. Many of the existing low pressure force mains are too small and would require enlargement or replacement depending on the location. With the low density of the area, the piping cost is a significant portion of the project. | |||||||||
| If the County decides to serve the infill lots, additional RIB's would have to be constructed and the biolac treatment system will have to be expanded. The use of adjacent lands for the RIB's would have to be investigated. This is still underway. Without additional disposal sites nearby the expansion is not feasible. The County wide Facility Plan will identify the number of EDU's that need service and the number of fill-in lots that can be served. This would then be taken to the Planning Commission and the Board of County Commissioners for their respective actions. | |||||||||
| PLANNING JUSTIFICATION: | |||||||||
| The County Environmental Health Department, Land Use and Growth Management have expressed interest in servicing the area. Many of the homes with failing septic systems are within the critical area zone and need public sewer service. | |||||||||
| LOCATION: | |||||||||
| 2nd Sanitary District | |||||||||
| PROJECT TITLE | PROJ. NO. | PROJECT CLASSIFICATION | |||||||
| SCS Plant & System Expansion | 2-11-S | Sewer | |||||||
| COST CENTER | Sewer | Water | Total Project | ||||||
| Planning | $75,000 | $0 | $75,000 | ||||||
| Engineer / Design | $165,000 | $0 | $165,000 | ||||||
| Land Acquisition | $0 | $0 | $0 | ||||||
| Construction | $1,400,000 | $0 | $1,400,000 | ||||||
| Overhead | $160,000 | $0 | $160,000 | ||||||
| Other | $0 | $0 | $0 | ||||||
| Total | $1,800,000 | $0 | $1,800,000 | ||||||
| Service Area Expansion% | 50.0% | 0.0% | |||||||
| Capital Facilities Expansion% | 50.0% | 0.0% | |||||||
| Upgrade/Replacement% | 0.0% | 0.0% | |||||||
| Other Sources% | 0.0% | 0.0% | |||||||
| Spent | Five Year Capital Improvement Budget | Total | |||||||
| APPROPRIATION | FY07 | FY 2008 | FY 2009 | FY 2010 | FY 2011 | FY 2012 | Project | ||
| SEWER | $13,400 | $166,600 | $1,620,000 | $0 | $0 | $0 | $1,800,000 | ||
| WATER | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| TOTAL COSTS | $13,400 | $166,600 | $1,620,000 | $0 | $0 | $0 | $1,800,000 | ||
| FUNDING SOURCE | Spent | Five Year Capital Improvement Budget | Total | ||||||
| FUNDS: | FY07 | FY 2008 | FY 2009 | FY 2010 | FY 2011 | FY 2012 | Project | ||
| LOANS | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| BONDS | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| GRANTS | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| NAVY | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| RESERVES | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| COUNTY FUNDS | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| STATE FUNDS | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| FEDERAL FUNDS | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| OTHER SOURCES | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| specify: | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||
| TOTAL FUNDS | $0 | $0 | $0 | $0 | $0 | $0 | $0 | ||